小鼠双调卵白(AREG)酶联免疫吸附检测试剂盒
ELK1003
金狮贵宾会-宾至如归-尊贵-显赫规格: 金狮贵宾会-宾至如归-尊贵-显赫价钱:
48T ¥1680.00
96T ¥2400.00

Overview 文献

Product name: Mouse AREG(Amphiregulin) ELISA Kit
Reactivity: Mouse
Alternative Names: AR; CRDGF; SDGF; Colorectum Cell-Derived Growth Factor; Schwannoma-Derived Growth Factor
Assay Type: Sandwich
Sensitivity: 5.8 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;
Uniprot ID: P31955
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse AREG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse AREG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse AREG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse AREG in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Investigative Ophthalmology & Visual Science

    Subconjunctival Injection of Regulatory T Cells Potentiates Corneal Healing Via Orchestrating Inflammation and Tissue Repair After Acute Alkali Burn

    金狮贵宾会-宾至如归-尊贵-显赫日期:2021-12-28 金狮贵宾会-宾至如归-尊贵-显赫IF:4.799

标准曲线

Concentration (pg/mL) OD Corrected OD
1000.00 2.154 2.046
500.00 1.647 1.539
250.00 1.157 1.049
125.00 0.726 0.618
62.50 0.514 0.406
31.25 0.318 0.210
15.63 0.216 0.108
0.00 0.108 0.000
金狮贵宾会-宾至如归-尊贵-显赫

细密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

接纳率

Matrices listed below were spiked with certain level of recombinant AREG and the recovery rates were calculated by comparing the measured value to the expected amount of AREG in samples.
Matrix Recovery range Average
serum(n=5) 93-101% 97%
EDTA plasma(n=5) 85-103% 94%
Heparin plasma(n=5) 95-105% 100%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AREG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 85-96% 93-102% 95-104%
EDTA plasma(n=5) 86-97% 91-102% 81-97% 93-107%
Heparin plasma(n=5) 82-94% 83-96% 91-103% 82-99%